DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 48
11.16 Open/Close Report Control Programming: Program Address (0187)
If programmed, these reports are sent when the
system is armed or disarmed. They may be sent
independently for the opening and closing of each
partition, or the first partition to open and the last
partition to close may send the reports.
See Glossary (section 6.12) for further details.
11.17 Open/Close & Zone Report Control Programming: Program Address (0189)
This section allows you to decide which phone number will send open and close reports, zone alarm, zone restoral, and zone trouble
reports.
11.18 Report Control Programming: Program Address (0190)
This section allows you to decide which phone number will send reports other than open/close reports and zone reports.
4
Select Options
0 1 2 3 5 6 7
8
9
Do not report opens or closes
Report opens and closes in Partition 1
Report opens and closes in Partition 2
Report opens and closes in Partition 3
Report first Partition to open and last
Partition to close**
Report opens and closes in Partition 4
Enter the Data Digit as a:
Send Closing and
Bypass reports after
Send Closing and
Bypass reports at close
1
0
Report opens and closes in Partition 5
Report opens and closes in Partition 6
Report opens and closes in Partition 7
Report opens and closes in Partition 8
exit delay
** = When using this option, all partitions should have the same account code.
Data Dig
it
12
Data Digit
12
0
Example:
To program to send Open/Close Reports from Partition 1 and to send
Trouble Reports on Closings for all Bypassed Zones.
Data Digit 1 = [1], Data Digit 2 = [1].
Enter the Programmer’s Mode: [9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [8] [7]
Enter Data Digit 1: [1]
Enter Data Digit 2: [1]
Enter the pound key: [#]
Program the next Address, Program a different Address, or Exit the
Programmer’s Mode.
Example:
To program to send Open and Close Reports
to Phone Number 1 and Zone Alarm, Zone
Restoral, and Zone Trouble Reports to Phone
Number 2.
Data Digit 1 = [1], Data Digit 2 = [2].
Enter the Programmer’s Mode:
[9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [8] [9]
Enter Data Digit 1: [1]
Enter Data Digit 2: [2]
Enter the pound key: [#]
Program the next Address, Program a differ-
ent Address, or Exit the Programmer’s Mode.
Example:
To program all other Reports to Phone Num-
ber 2.
Data Digit 1 = [2], Data Digit 2 = [0].
Enter the Programmer’s Mode:
[9] [8] [7] [6] [#] [0]
Enter the Program Address: [0] [1] [9] [0]
Enter Data Digit 1: [2]
Enter Data Digit 2: [0]
Enter the pound key: [#]
Program the next Address, Program a differ-
ent Address, or Exit the Programmer’s Mode.
Data Digit 2
is for Zone Alarm,
Zone Restoral,
Zone Trouble,
Bypass, Unbypass,
and Trouble
Restoral Reports
DDSelect Option
DD
Alternate between both Phone Numbers
0
0
Alternate between both Phone Numbers
Report to Phone Number 1
Report to Phone Number 2
1
2
Report to Phone Number 1 and 2
3
Report to Phone Number 1
Report to Phone Number 2
1
2
Report to Phone Number 1 and 2
3
12
Data Digit 1 is
for Open and
Close Reports.
Select Option
Data Digit
Note:
Data Digit
1 does not
include open and
close reports or
zone reports (see
sections 11.16
and 11.17).
DD
Alternate between both Phone Numbers
0
Report to Phone Number 1
Report to Phone Number 2
1
2
Report to Phone Number 1 and 2
3
12
Select Option
D
a
t
a
D
i
g
i
t
0
Data Digit 2
must be 0
Seitenansicht 47
1 2 ... 43 44 45 46 47 48 49 50 51 52 53 ... 91 92

Kommentare zu diesen Handbüchern

Keine Kommentare

PULSE Showerspas 1019 Aqua Rain manuales

Manuales del propietario y guías del usuario para Para Casa PULSE Showerspas 1019 Aqua Rain.
Ofrecemos 1 manuales en pdf PULSE Showerspas 1019 Aqua Rain para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Para Casa PULSE Showerspas

Modelos Tipo de documento
1039W-BN Tropicana Manual de usuario   PULSE ShowerSpas 1039W-BN Tropicana User Manual, 8 paginas
1049B-BN Rio Manual de usuario   PULSE ShowerSpas 1049B-BN Rio User Manual, 8 paginas
1047W-CH Mirage Manual de usuario   PULSE ShowerSpas 1047W-CH Mirage User Manual, 8 paginas
1048B-BN Niagara Manual de usuario   PULSE ShowerSpas 1048B-BN Niagara User Manual, 8 paginas
1032 Hanalei Manual de usuario   PULSE ShowerSpas 1032 Hanalei User Manual, 5 paginas
1032 Hanalei Manual de usuario   PULSE ShowerSpas 1032 Hanalei Manuel d'utilisation, 8 paginas
1007 Kailua (silver) Manual de usuario   PULSE ShowerSpas 1007 Kailua (silver) User Manual, 2 paginas
1007 Kailua (white) Manual de usuario   PULSE ShowerSpas 1007 Kailua (white) User Manual, 2 paginas
1013-GL Kihei II Manual de usuario   PULSE ShowerSpas 1013-GL Kihei II User Manual, 8 paginas
1005 Kona Manual de usuario   PULSE ShowerSpas 1005 Kona User Manual, 2 paginas
1030 Lahaina Manual de usuario   PULSE ShowerSpas 1030 Lahaina User Manual, 8 paginas
1022-B Leilani Manual de usuario   PULSE ShowerSpas 1022-B Leilani User Manual, 8 paginas
1015-2 Makena II Manual de usuario   PULSE ShowerSpas 1015-2 Makena II User Manual, 8 paginas
1015-2 Makena II Manual de usuario   PULSE ShowerSpas 1015-2 Makena II Manuel d'utilisation, 8 paginas
1002 Maui Manual de usuario   PULSE ShowerSpas 1002 Maui User Manual, 8 paginas
1016 Mojave Manual de usuario   PULSE ShowerSpas 1016 Mojave User Manual, 8 paginas
1006-ORB Molokai Manual de usuario   PULSE ShowerSpas 1006-ORB Molokai User Manual, 2 paginas
1038 Nature Rain Manual de usuario   PULSE ShowerSpas 1038 Nature Rain User Manual, 4 paginas
1018 Navajo Manual de usuario   PULSE ShowerSpas 1018 Navajo User Manual, 4 paginas
1035 Oahu Manual de usuario   PULSE ShowerSpas 1035 Oahu User Manual, 8 paginas