DS7400Xi Ver. 3+ Reference Guide Copyright © 2004 Detection Systems, Inc. P/N: 28995K Page 32
8.0 Keypads
8.1 The Master Keypad
Your system may include a Master keypad.
A Master keypad is a DS7447/DS7447E keypad programmed to give a user access to all the partitions he has access to, not just the
partition the Master keypad is in. This is different from a Standard keypad in that Standard keypads only give access to the single partition
they are in. Commands entered at the Master keypad will affect all the partitions the user has access to. If this is not desirable, the Master
keypad can be used to control partitions individually; this is called Single Partition Mode. Single Partition Mode allows a user to control
the partitions he has access to on an individual (one by one) basis (see section 8.4 for more information on Single Partition Mode).
8.2 Master Keypad Displays
Master keypad displays will differ slightly from Standard keypads.
The Master keypad display will scroll the Status of each partition, followed by the partition number.
For example, if all partitions are armed, the Master keypad will scroll through the following displays:
Armed Armed Armed Armed Armed Armed Armed Armed
Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8
If only partitions 1, 2, 3, 4, 6, and 8 are armed, the Master keypad will scroll through the following displays:
Armed Armed Armed Armed Ready to Arm Armed Ready to Arm Armed
Area 1 Area 2 Area 3 Area 4 Area 5 Area 6 Area 7 Area 8
Displays for partitions that are Not Ready will display in the same manner.
All partitions are disarmed.
Not ready to arm (if the
Armed Light is on, all
partitions are armed).
The control panel has lost
all power; no AC or battery.
There are no fire alarms.
Armed
(red)
Status
(green)
Power
(green)
Fire
(red)
All partitions are armed, and no alarms have
occurred.
All partitions are ready to arm.
Normal Operation.
The control panel is running on AC power
with no problems.
A fire trouble condition exists.
One or more partitions
are armed, or an alarm
has occurred.
One or more zones are
bypassed.
Control panel problems
exist. See Error Displays.
A fire zone is in alarm.
Light Off Flashing On
8.3 Arming from the Master Keypad
Arming all the
Partitions you
have access to.
Arming from the Master Keypad
Enter your PIN followed by one of the arming sequences.
This will alarm all of your partitions, even if some are already armed.
You must enter Single Partition Mode to arm the necessary partitions one at a time.
Arming only
some of your
Partitions
1. Enter your [PIN], followed by the [#] key twice: [1] [2] [3] [4] [#] [#].
2. The first partition you have access to will be displayed:
"Ready to Arm. Cafeteria."
3. Complete the arming command sequence you wish for this partition: [On].
4. Move to the next partition you have access to by pressing the [#] key twice: [#] [#].
5. The next partition you have access to will be displayed:
"Ready to Arm. Office."
6. Complete the arming command sequence you wish for this partition.
7. After you have completed all the arming command sequences for the partitions
you have access to, exit Single Partition Mode by pressing the [*] key for 2 seconds.
Seitenansicht 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 91 92

Kommentare zu diesen Handbüchern

Keine Kommentare

Rainbow-electronics MAX913 manuali

Manuali dei proprietari e guide per l'utente per Ricevitori e amplificatori Rainbow-electronics MAX913.
We fornisce 1 manuali pdf Rainbow-electronics MAX913 per scaricare gratuitamente in base al tipo di documento: Manuale Utente






Più prodotti e manuali per Ricevitori e amplificatori Rainbow-electronics

Modelli Tipo di Documento
MAX909 Manuale Utente   Rainbow Electronics MAX909 User Manual, 10 pagine
MAX924 Manuale Utente   Rainbow Electronics MAX924 User Manual, 16 pagine
MAX1574 Manuale Utente   Rainbow Electronics MAX1574 User Manual, 9 pagine
MAX903 Manuale Utente   Rainbow Electronics MAX903 User Manual, 12 pagine
MAX3738 Manuale Utente   Rainbow Electronics MAX3738 User Manual, 14 pagine
MAX977 Manuale Utente   Rainbow Electronics MAX977 User Manual, 16 pagine
MAX479 Manuale Utente   Rainbow Electronics MAX479 User Manual, 12 pagine
MAX996 Manuale Utente   Rainbow Electronics MAX996 User Manual, 12 pagine
MAX944 Manuale Utente   Rainbow Electronics MAX944 User Manual, 11 pagine
LMX339 Manuale Utente   Rainbow Electronics LMX339 User Manual, 12 pagine
MAX480 Manuale Utente   Rainbow Electronics MAX480 User Manual, 6 pagine
MAX920 Manuale Utente   Rainbow Electronics MAX920 User Manual, 12 pagine
MAX999 Manuale Utente   Rainbow Electronics MAX999 User Manual, 12 pagine
MAX998 Manuale Utente   Rainbow Electronics MAX998 User Manual, 8 pagine
MAX2055 Manuale Utente   Rainbow Electronics MAX2055 User Manual, 13 pagine
BA14741F Manuale Utente   Rainbow Electronics BA14741F User Manual, 4 pagine
BA10324AFV Manuale Utente   Rainbow Electronics BA10324AFV User Manual, 5 pagine
BA10393F Manuale Utente   Rainbow Electronics BA10393F User Manual, 4 pagine
BA4558N Manuale Utente   Rainbow Electronics BA4558N User Manual, 5 pagine
BA15532N Manuale Utente   Rainbow Electronics BA15532N User Manual [en] [ru] [de] [cs] , 4 pagine