Code Alarm CA-535 Installationsanleitung Seite 19

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 33
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 18
4 -
Black/Yellow Output :
Controls
the BLACK/YELLOW output activation type and
timing.
Pulse During
Crank
- Output becomes active with the same timing as the
starter output wire, during crank
only.
Ground
While
Running - Continuous output for the entire remote start
sequence
until after the vehicle
shuts down.
Ignition
- Output becomes active with the same timing as the ignition output
and does not drop out during crank.
Accessory - Output becomes active with the same timing as the accessory
output, drops out during crank.
Transmitter Button Functions
2014 Voxx
Electronics
Corporation. All
rights reserved.
19
Seitenansicht 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 32 33

Kommentare zu diesen Handbüchern

Keine Kommentare