Multi-Zone Gas Monitors
24 P/N: 3015-5074 Rev 13
Jumper the “Live/Positive” line of an external power source (DC devices) or the monitor’s AC input (AC
devices) to the “Commonterminal on the relay connector.
Connect theLive/Positiveend of the strobe or horn to the “NOterminal of whichever level of alarm is
appropriate for the application.
For protection, install an in-line fuse of the appropriate size and design for the external alarm device being
used.
The other end of the strobe or horn is connected to the Neutral/Negativeleg of the external power
source (DC devices) or monitor’s AC input (AC devices).
Figure 2-14. Typical AC External Alarm Relay 1 Wiring
Figure 2-15. Typical DC External Alarm Relay 1 Wiring