ALARM INPUTS TB1-1 thru TB1-8
The external dry relay contacts, representing the alarms, are connected to terminals 1 to 8 in
-
clusive. These optically coupled inputs sense alarm activity by either a closure to ground or
an open circuit. Programming options select either normally open (NO) or normally closed
(NC) alarm contacts. The alarm ground must be the same as the power ground. Do not ap
-
ply any voltage source to the input terminals. Active current on each input is 100 mA.
RELAY OUTPUTS TB2
Four form C relay contacts are available on TB2. Table 1 shows the connections available at
each pin. The relays are controlled by receiving DTMF digits from the radio system
(through the master) that correspond to its internally programmed parameters. Refer to the
programming section for further details.
SERIAL IN / SERIAL OUT PORTS P3, P4
Connections from the master to the expander and between expanders are made to P3 and P4
using a shielded single cable conductor. This connection allows data to be transferred be
-
tween the master and the expanders.
ALWAYS power up both the expander and ARU together AFTER this communication cable
has been connected. Failure to do so could cause damage to one or both units.
B1225E BARNETT ENGINEERING LTD. PAGE 4
7
8 Relay 3
9
4
5
6
2
3
common
1
10
11 Relay 4
12
Relay 1
Relay 2
NO contact
TB2 FUNCTION
common
common
common
NO contact
NO contact
NO contact
NC contact
NC contact
NC contact
NC contact
TABLE 1 RELAY CONNECTIONS